Monthly archives: May 2015

Entries found: 5

SELF-ADJUSTABLE CLAMP RING WITH BELT

 

Self-adjustable clamp ring with belt    is made of high quality Poliamid, self-extinguishable V0, resistant to heating 110C without deformation. It is produced in grey colour RAL 7035. It is intended for tightening all types of electro , plumbing pipes, heating and gas pipes, for direct tightening of cables on the walls, ceiling, poles, electrical cabinats. Advantages:

Simple and fast mounting on all types of installation with greatest possible saving of work hours. Self-adjustable clamp ring with belt is intended for the places where good mechanical connection is needed, where there is higher temperature and they are suitable for outside use due to their resistance to UV rays. With only two type of self-adjustable clamp ring with belt the outside dimension comprise fi 15-42mm which substantially make assembly work easier.

SELF-ADJUSTABLE CLAMP RING WITH BELT SELF-ADJUSTABLE CLAMP RING WITH BELT

Code number Opening diameter mm Package pcs Weight kg/100pcs
5340100 Ø15-25 100 0.5
5340102 Ø24-42 100 1

 

COUPLINGS

COUPLINGS

These couplings are made of PVC or polyamide. Polyamide couplings with glass fibers are used where high tension strength is needed. Conform to DIN 46320 standards. Couplings are self-extinguishable and resistant to UV-rays and weather conditions. Currently, these are the only couplings being used as they offer complete protection from contact with voltage.

 

 Code number

PVC                              Polyamid

Type Thread  PG(Re For cabel diameter mm Package pcs Weight kg/100pcs
5300091 5300071 FU PG-13,5 13,5 8-12 100 1,1/1,5
5300092 5300072 FU PG-16 16 10-14 100 1,5/1,8
5300093 5300073 FU PG-21 21 13-18 100 2,6/2,8
5300094 5300074 FU PG-29 29 18-25 100 3,6/4,3
5300095 5300075 FU PG-36 36 22-32 100 7,2/8,5

 

ARMORED FUSES

 

Armored fuses are used to secure residential connections for installation inside attics or in fuse boxes. The housing is made of thermoplastic. At customers demand, they can be delivered with 25 and 63A fuses (indicate when ordering).

 

Code number Type Lenght mm Width mm Package pcs Weight kg/pcs
5100020 63A 226 150 10 1.40
5100026 25A 226 150 10 1.20

FUSE SWITCH DISCONNECTORS

 

Used for protection of electrical grid from short-circuiting and overloading . Intended for install ationon collectors . Easily installed, take up little free space on the installation board . Housing is made of self – extingu is hable polyester reinforced with fiberglass.

FUSE SWITCH DISCONNECTORS

Code number Type Rated current A Rated voltage V Insulation voltage V Package pcs
5400115 FHOO-160/1 160 690 1000 1
5400116 FHOO-160/3 160 690 1000 1
5400124 FH1-250/1 250 690 1000 1
5400125 FH1-250/3 250 690 1000 1
5400139 FH2-400/1 400 690 1000 1
5400140 FH2-400/3 400 690 1000 1
5400162 FH3-630/1 630 690 1000 1
5400163 FH3-630/3 630 690 1000 1

 

DISJUNCTIVE FUSE BASE

 

Used for protection of electrical grid from short-circuiting and overloading. Intended for installation on collectors. Easily installed, take up little free space on the installation board and they guarantee protection from accidental contact. Housing is made of self-extinguishable polyester reinforced with fiberglass.

DISJUNCTIVE FUSE BASE

Code number Type Rated current A Rated voltage V Insulation voltage V The distance rail mm
5400037 SLOO-160/3 160 690 750 100
5400031 FD1-160-3 160 690 1000 185
5400032 FD1-250/3 250 690 1000 185
5400033 FD2-400/3 400 690 1000 185
5400034 FD3-630/3 630 690 1000 185

 

FUSE RAILS

 

Used for protection of electrical grid from short-circuiting and overloading. Intended for installation on collectors. Easily installed, take up little free space on the installation board. Housing is made of self-extinguishable polyester reinforced with fiberglass.

FUSE RAILS

Code number Type Rated current A Rated voltaage V Insulation voltage V Package pc
5400041 L00 – 160/3 160 690 750 1
5400042 FR1 – 250/3 250 690 1000 1
5400043 FR2 – 400/3 400 690 1000 1
5400044 FR3 – 630/3 630 690 1000 1

 

DISJUNCTIVE 3-POLE FUSE BASE 50 A (ø14×51)

 

Used for protection of electrical grid from short-circuiting and overloading. Intended for montage on rails 35mm wide, and for maximum current up to 50A. It is used with cylinder fuses Ø14x51mm for rated current 2, 4, 6, 8, 10, 12, 16, 20, 25, 32, 40 or 50A. Sealing can be done in switched on and switched off position, with and without electric arc fuse. Incoming and outgoing conductors can be connected without screwing, in conductors range 1.5 up to 35 mm².

 

  •     Dimension:81x112x102 mm DISJUNCTIVE 3-POLE FUSE BASE 50 A (ø14x51)
  • Weight: 33 kg/100 kom
  • Code number: 5400250

THREE-POLE KNIFE-BLADE FUSE BASE

 

Used for protection of electrical networks from short circuiting and overloads.
Note: Protective elements are delivered separately and are used as additional protection for accidental contact with parts under voltage.

THREE-POLE KNIFE-BLADE FUSE BASE

Code number Type In A Package pcs Weight kg/pcs
5410103 FPK 160/3 160 1 0.56
5410253 FPK 250/3 250 1 1.76
5410403 FPK 400/3 400 1 3.07

 

SINGLE-POLE KNIFE-BLADE FUSE BASE

Used for protection of electrical networks from short circuiting and overloads.
Note: Protective elements are delivered separately and are used as additional protection for accidental contact with parts under

SINGLE-POLE KNIFE-BLADE FUSE BASESINGLE-POLE KNIFE-BLADE FUSE BASE

Code number Type In A Package pcs Weight kg/pcs
5410101 FPK 160/1 160 3 0.18
5410251 FPK 250/1 250 3 0.59
5410401 FPK 400/1 400 3 1.03

 

HANDLE FOR KNIFE-BLADE FUSES

 

Used for placing and removing knife-blade fuses NV-00 to NV-03. The handle is made of insulated thermoplastic and can be used without protective gloves.HANDLE FOR KNIFE-BLADE FUSES

Code number Type In A Package pcs Weight kg/pcs
5410001 NV-00-3 2-630 10 0.27
5410002 PROTECTED 2-630 10 0.50

 

Page 20 of 42« First...10«1819202122»3040...Last »