CONNECTOR FOR BRANCHING AND CONNECTING MULTI-WIRE CABLES
Used for connecting and branching of cables without cutting the main feed and without remove the insulation. By pressing over the cable with combination pliers.
Code number | Designation mm²/Bolt M | L mm | Package pcs | Weight g/100pcs |
1400015 | FKRS 1.5 | 19.5 | 50/200 | 175 |
1400025 | FKRS 2.5 | 19.5 | 50/200 | 175 |
INSULATING SCREW-ON MULTI-WIRE CONNECTORS
Used for connecting small diameter cables. Connection is made by screwing the connector over the wire.
Code number | Designation mm²/Bolt M | L mm | Package pcs | Weight g/100pcs |
1402125 | FSKZ 1.5-25 | 21.5 | 50-250 | 150 |
1402406 | FSKZ 4-6 | 24 | 50-250 | 176 |
INSULATED CRIMPED MULTI-WIRE CONNECTORS
Used for connecting and branching of conductors in distribution boxes for electrical installation and in auto wiring. Wire connections made by crimping.
Code number | Designation mm²/Bolt M | L mm | Package pcs | Weight g/100pcs |
1401015 | FSKP 1.5-2.5 | 15.0 | 100/1000 | 60 |
1401046 | FSKP 4-6 | 17.0 | 100/500 | 98 |
INSULATED BUTT CONNECTORS FOR EXTENDING CABLES
Used for extending cables of the same diameter. Connection is made by crimping.
Code number | Designation mm²/Bolt M | L mm | Package pcs | Weight g/100pcs |
1400105 | FOG – 1.5 | 25.0 | 100/1000 | 124 |
1400205 | FOG – 2.5 | 25.0 | 100/1000 | 160 |
1400406 | FOG – 4-6 | 27.0 | 100/500 | 251 |
NON-INSULATED MULTI-WIRE TERMINALS – DIN 46228
Used for terminating and connecting multi-wire conductors in the electrical circuits of electrical cabinets and devices.
Code number | Designation mm²/Bolt M | L mm | Package pcs | Weight g/100pcs |
1310708 | FNH-0.75 | 8.0 | 1000/10000 | 45 |
1311008 | FNH-1 | 8.0 | 1000/10000 | 65 |
1311508 | FNH-1.5 | 8.0 | 1000/10000 | 78 |
1312510 | FNH-2.5 | 10.0 | 1000/10000 | 103 |
13144010 | FNH-4 | 10.0 | 1000/10000 | 164 |
INSULATED PIG TAIL TERMINALS FOR MULTI-WIRE CONDUCTORS – DIN 46228
Used for terminating and connecting multi-wire conductors in the electrical circuits of electrical cabinets and devices.
Code number | Designation mm²/Bolt M | L mm | P mm | Package pcs | Weight g/100pcs |
1300508 | FZH-0.5 | 14.0 | 8 | 500/7000 | 7.4 |
1300708 | FZH-0.75 | 14.0 | 8 | 500/7000 | 9.0 |
1301008 | FZH-1 | 14.0 | 8 | 500/6000 | 9.2 |
1301510 | FZH-1.5 | 14.0 | 10 | 500/4000 | 13.2 |
1302510 | FZH-2.5 | 16.0 | 10 | 500/3000 | 18.2 |
1304012 | FZH-4 | 20.0 | 12 | 500/2000 | 32.0 |
1306012 | FZH-6 | 20.0 | 12 | 500/1500 | 42.2 |
1310012 | FZH-10 | 22.0 | 12 | 500/500 | 59.8 |
PIN TYPE NON-INSULATED CABLE TERMINALS – DIN 46234
Used for terminating and connecting multi-wire conductors in the electrical circuits of electrical cabinets and devices.
Code number | Designation mm²/Bolt M | L mm | P mm | Package pcs | Weight g/100pcs |
1110015 | FIP-1.5/N | 17.5 | 12.5 | 100/1000 | 57 |
1110046 | FIP-4.6/N | 21.0 | 14.5 | 100/600 | 144 |
PIN TYPE INSULATED CABLE TERMINALS
Used for terminating and connecting multi-wire conductors in the electrical circuits of electrical cabinets and devices.
Code number | Designation mm²/Bolt M | L mm | P mm | Package pcs | Weight g/100pcs |
1110116 | FIP-1.5 | 21.5 | 12.0 | 100/1000 | 73 |
1110125 | FIP-2.5 | 21.5 | 12.0 | 100/1000 | 85 |
1110146 | FIP-6 | 27.5 | 13.0 | 100/500 | 174 |
SPADE TONGUE NON-INSULATED CABLE TERMINALS – DIN 46234
Used for terminating and connecting small diameter conductors in electrical circuits, contacts, relays, etc.
Code number | Designation mm²/Bolt M | L mm | K mm | Package pcs | Weight g/100pcs |
1201153 | FVP 1.5/3N | 16.3 | 6.3 | 100/2000 | 51 |
1201155 | FVP 1.5/5N | 16.0 | 8.0 | 100/4000 | 52 |
1201254 | FVP 2.5/4N | 16.0 | 8.0 | 100/3000 | 57 |
1201255 | FVP 2.5/5N | 16.0 | 8.0 | 100/3000 | 58 |
SPADE TONGUE INSULATED CABLE TERMINALS – DIN 46234
Used for terminating and connecting small diameter conductors in electrical unit circuits