TERMINAL BLOCK FOR GROUNDING
Construction is designed so that metal teeth (connection with rail) are at the same time used as a connection of the block and the grounding.
Code number | Designation mm² | Dimensions AxBxC | Package pcs | Mass kg/100pcs |
5000072 | FKU 2.5 | 24x55x7.5 | 100 | 1.0 |
5000076 | FKU 6 | 24x55x8.5 | 100 | 1.3 |
5000078 | FKU 16 | 28.5x55x11.5 | 50 | 2.4 |
COMMONING-RAIL FOR TERMINAL BLOCKS
Upon request we make and deliver commoning links with the desired number of poles.
Code number | Number of poles | For VS clamp | A mm | B mm | Package pcs | Weight pcs |
5000204 | 2 | FKN 2,5-4 | 7,8 | 6×1 | 10 | 0,70 |
5000206 | 2 | FKN 6 | 8,9 | 6×1 | 10 | 0,76 |
5000210 | 2 | FKN 10 | 10,2 | 6×1 | 10 | 0,82 |
5000216 | 2 | FKN 16 | 12,2 | 6×2 | 10 | 0,88 |
5000235 | 2 | FKN 25-35 | 21,1 | 6×2 | 10 | 0,94 |
5000236 | 3 | FKN 2,5-4 | 7,8 | 6×1 | 10 | 1,05 |
5000237 | 3 | FKN 6 | 8,9 | 6×1 | 10 | 1,14 |
5000238 | 3 | FKN 10 | 10,2 | 6×1 | 10 | 1,23 |
5000240 | 3 | FKN 16 | 12,2 | 6×2 | 10 | 1,32 |
5000242 | 3 | FKN 25-35 | 21,1 | 6×2 | 10 | 1,41 |
5000244 | 4 | FKN 2,5-4 | 7,8 | 6×1 | 10 | 1,40 |
5000246 | 4 | FKN 6 | 8,9 | 6×1 | 10 | 1,52 |
5000247 | 4 | FKN 10 | 10,2 | 6×1 | 10 | 1,64 |
5000248 | 4 | FKN 16 | 12,2 | 6×2 | 10 | 1,76 |
5000249 | 4 | FKN 25-35 | 21,1 | 6×2 | 10 | 1,88 |
5000250 | 5 | FKN 2,5-4 | 7,8 | 6×1 | 10 | 1,75 |
5000251 | 5 | FKN 6 | 8,9 | 6×1 | 10 | 1,90 |
5000252 | 5 | FKN 10 | 10,2 | 6×1 | 10 | 2,05 |
5000253 | 5 | FKN 16 | 12,2 | 6×2 | 10 | 2,20 |
5000254 | 5 | FKN 25-35 | 21,1 | 6×2 | 10 | 2,35 |
5000255 | 10 | FKN 2,5-4 | 7,8 | 6×1 | 10 | 3,50 |
5000260 | 10 | FKN 6 | 8,9 | 6×1 | 10 | 3,80 |
5000270 | 10 | FKN 10 | 10,2 | 6×1 | 10 | 4,10 |
5000275 | 10 | FKN 16 | 12,2 | 6×2 | 10 | 4,40 |
5000278 | 10 | FKN 25-35 | 21,1 | 6×2 | 10 | 4,70 |
5000281 | 2 pokr. | FKN 16 P | 12,2 | 6×1 | 10 | 0,60 |
5000282 | 2 nepokr. | FKN 26 P | 12,2 | 6×1 | 10 | 0,63 |
TERMINAL BLOCKS
Used for connection of measuring and switching boxes. Housing is made of high quality, imported plastic masses, with self-extinguishing properties V-0. Contacts are made of brass profiles which establish connection between copper and aluminium at the same time. Base of the clamp is universal and can be installed on every type of rails.
Code number | Type | Dimensions AxBxC | Package pcs | Mass kg/100pcs |
5000182 | FRS-4-16/2 | 30x72x22 | 50 | 7 |
5000183 | FRS 4-16/3 | 30x72x33 | 50 | 10.5 |
TERMINAL BLOCK RAIL – DIN RAIL
Used to support terminal blocks joined in a series. The advantage of this rail is that it is calibrated so that the teeth of the elements firmly attach to the rail. Thanks to its narrow tolerance, the rail will not crack.
LIMIT PLATE FOR TERMINAL BLOCKS
These plates are attached to the rail at the end of a block series. Thanks to the specially designed base, the plate fits all standard rails. The plate is made of high-quality polyamide.
- Package: 100 pcs
- Weight: 0,96 kg/100pcs
- Code number: 5000120
END CAP FOR TERMINAL BLOCKS
Used to end a series of clamps by closing the open part of the clamp. Also used for separating groups of clamps.
Code number | For VS clamp | AxB mm | Package pcs | Weight kg/100pcs |
5000104 | FKN 4-10 | 37×40 | 500 | 0.30 |
5000116 | FKN 16-35 | 42×50 | 500 | 0.42 |
5000117 | FKN 16P | 36×58 | 500 | 0.29 |
PARTITION PLATE FOR TERMINAL BLOCKS
Used for separating commoning link when making a series of VS clamps. Plate thickness is 0.5 mm.
- Package: 100 pcs
- Weight: 0,01 kg/100pcs
- Code numbers: 5000118
TERMINAL BLOCKS (VS-CLAMPS) SPANNING 1, 5 – 16 mm2 – WITH GEAR
Note: When connecting wire products to VS-clamps, always use insulated connectors or pin-type terminals, or solder the ends.
Code number | Designation mm² | Dimensions AxBxC | Package pcs | Weight kg/100pcs |
5000066 | FKN 16P | 53×50 | 50 | 3.20 |
5000281 | – | 50 | 0.60 | |
5000282 | – | 50 | 0.63 | |
5000284 | – | 50 | 0.90 |
TERMINAL BLOCKS (VS – CLAMPS)
Currently, the housing of FEMAN’s terminal blocks is made exclusively from the highest quality imported plastic materials, self-extinguishing V-0, and has an insulation value of 750 V, as well as heat resistance to 1100°C without deforming. The block bases are constructed to fit all types of existing rails. FEMAN VS-clamps are completely made according to VDE – DIN standards for this type of product. Along with additional sizes of clamps ( 2,5 – 35 mm2 ), FEMAN makes all the accompanying gear/elements. In recent years, FEMAN has proven the quality of their terminal blocks, and the best evidence of this is the several million elements of all different sizes delivered and installed.
Code number | Type | Dimension AxBxC | Packing pcs | Weight kg/100pcs |
5000004 | FKN 2.5-4 | 48x40x7 | 120 | 1.31 |
5000006 | FKN 6 | 48x40x9 | 100 | 1.80 |
5000010 | FKN 10 | 48x40x10 | 100 | 2.20 |
5000016 | FKN 16 | 53x50x12 | 50 | 2.93 |
5000035 | FKN 25-35 | 53x50x15 | 50 | 4.75 |
FEFIX clamp
Feman Fix clamp is used for connecting and terminating aluminum- steel lines at all connection points where exceptional connection strength is needed, in accordance with JUS N.F4.106.Convenient for quick assembly and disassembly since only one wrench is needed; no need for a counter wrench. Grooves add 48 additional strength to the connection.
Code number | Designation mm²/Bolt M | For diameter mm | Package pcs | Weight g/100pcs |
3003550 | FEFIX 350-50 | 7,5-9,5 | 25 | 16,80 |