Yearly archives: 2015
Entries found: 10
ALUMINUM-COPPER CABLE TERMINALS FOR CRIMPING
Used for terminating Al cable & switching to Cu rod in elect. circuit of device manufactured in accordance with JUS.N.F4.101
Code number |
Designation mm²/Bolt M |
d1 | d2 | d3 | L1 | L2 | No. of crimps mech./hidr. |
Package pcs |
Weight g/100pcs |
mm | mm | mm | mm | mm | |||||
1901608 | FACP-16/8 | 8,5 | 5,5 | 11,0 | 53,0 | 16,5 | 4-2 | 100 | 1,20 |
1902508 | FACP-25/8 | 8,5 | 6,8 | 12,0 | 53,0 | 16,5 | 4-2 | 100 | 1,55 |
1903508 | FACP-35/8 | 8,5 | 8,0 | 14,0 | 57,5 | 18,5 | 5-2 | 100 | 1,75 |
1903510 | FACP-35/10 | 10,5 | 8,0 | 14,0 | 57,5 | 18,5 | 5-2 | 100 | 1,75 |
1903512 | FACP-35/12 | 13,0 | 8,0 | 14,0 | 57,5 | 18,5 | 5-2 | 100 | 1,75 |
1905008 | FACP-50/8 | 8,5 | 10,0 | 15,6 | 66,5 | 20,5 | 5-2 | 100 | 2,50 |
1905010 | FACP-50/10 | 10,5 | 9,3 | 15,6 | 66,5 | 20,5 | 5-2 | 100 | 2,50 |
1907010 | FACP-70/10 | 10,5 | 11,0 | 18,0 | 72,0 | 24,5 | 6-3 | 100 | 3,40 |
1907012 | FACP-70/12 | 13,0 | 11,0 | 18,0 | 72,0 | 24,5 | 6-3 | 100 | 3,60 |
1909510 | FACP-95/10 | 10,5 | 13,1 | 22,0 | 88,0 | 30,3 | 6-3 | 100 | 5,50 |
1909512 | FACP-95/12 | 13,0 | 13,1 | 22,0 | 88,0 | 30,3 | 6-3 | 100 | 5,50 |
1912010 | FACP-120/10 | 10,5 | 15,0 | 22,0 | 104,0 | 30,7 | 6-3 | 50 | 6,00 |
1912012 | FACP-120/12 | 13,0 | 15,0 | 22,0 | 104,0 | 30,7 | 6-3 | 50 | 6,00 |
1915012 | FACP-150/12 | 13,0 | 16,9 | 25,5 | 117,5 | 35,7 | 6-3 | 50 | 9,60 |
1915016 | FACP-150/16 | 17,0 | 16,9 | 25,5 | 117,5 | 35,7 | 6-3 | 50 | 9,60 |
1918512 | FACP-185/12 | 13,0 | 18,0 | 28,0 | 121,5 | 37,8 | 6-3 | 25 | 12,34 |
1918516 | FACP-185/16 | 17,0 | 18,0 | 28,0 | 121,5 | 37,8 | 6-3 | 25 | 12,34 |
1924012 | FACP-240/12 | 13,0 | 21,0 | 32,0 | 140,0 | 44,0 | 8-3 | 25 | 18,28 |
1924016 | FACP-240/16 | 17,0 | 21,0 | 32,0 | 140,0 | 44,0 | 8-3 | 25 | 18,28 |
1930012 | FACP-300/12 | 13,0 | 23,5 | 35,5 | 159,0 | 48,6 | 8-3 | 25 | 25,50 |
1930016 | FACP-300/16 | 17,0 | 23,5 | 35,5 | 159,0 | 48,6 | 8-3 | 25 | 25,50 |
Bolt on cable terminals
Used for terminating Cu wires and power cables ( without the use of a crimper), according to JUS N.F4.101. Protected from corrosion by galvanization.
Code number | Designation mm²/Bolt M | d1 mm | d2 mm | L1 mm | L2 mm | Package pcs | Weight g/100pcs |
3601006 | FPV-10/6 | 6,5 | 3,8 | 33 | 19 | 200 | 1,00 |
3601606 | FPV-16/6 | 6,5 | 5,8-5,3 | 38 | 21 | 200 | 1,60 |
3602508 | FPV-25/8 | 8,5 | 5,3-6,7 | 42 | 23 | 200 | 2,20 |
3603508 | FPV-35/8 | 8,5 | 6,7-8 | 48 | 24 | 100 | 3,30 |
3603510 | FPV-35/10 | 10,5 | 6,7-8 | 57 | 24 | 100 | 3,50 |
3605010 | FPV-50/10 | 10,5 | 8-9 | 57 | 28 | 100 | 4,60 |
3607010 | FPV-70/10 | 10,5 | 9-10,5 | 60 | 30 | 100 | 6,00 |
3609512 | FPV-95/12 | 13,0 | 10,5-13,5 | 69 | 32 | 50 | 8,50 |
3612012 | FPV-120/12 | 13,0 | 13,5-15 | 72 | 40 | 50 | 16,00 |
3612012 | FPV-150/12 | 13,0 | 15-16,5 | 80 | 42 | 25 | 19,90 |
3615016 | FPV-150/16 | 17,0 | 15-16,5 | 80 | 42 | 25 | 19,80 |
COPPER BARREL-TYPE TERMINALS FOR CRIMPING
In accordance with DIN 46235
Material: Electrolytic copper DIN 40500 Surface: Zinc coated
Used for terminating copper cables (VDE 0295) and ropes (DIN 48201) in power cables, and connection to the electrical circuit by meansof a bolt and nut. Made with a control opening.
At the customer’s request we also make special order terminals.
Code number | Designation mm²/Bolt M | d1 mm | d2 mm | d3 mm | L1 mm | L2 mm | Number of crimps mech./hidr. | Package pcs | Weight g/100pcs |
700605 | FCPC-u6/5 | 5,2 | 3,5 | 6,5 | 26 | 11,5 | 2/- | 200 | 0,50 |
700606 | FCPC-u | 6,2 | 3,5 | 6,5 | 26 | 11,5 | 2/- | 200 | 0,50 |
700608 | FCPC-u | 8,2 | 3,5 | 6,5 | 26 | 14,0 | 2/- | 200 | 0,57 |
700610 | FCPC-u | 10,2 | 3,5 | 6,5 | 26 | 14,0 | 2/- | 200 | 0,67 |
701006 | FCPC-u | 6,2 | 4,5 | 7,0 | 29 | 9,4 | 2/- | 200 | 0,56 |
701008 | FCPC-u | 8,2 | 4,5 | 7,0 | 29 | 12,5 | 2/- | 200 | 0,62 |
701010 | FCPC-u | 10,2 | 4,5 | 7,0 | 29 | 17,3 | 2/- | 200 | 0,85 |
701012 | FCPC-u | 12,2 | 4,5 | 7,0 | 29 | 17,3 | 2/- | 200 | 0,86 |
701608 | FCPC-u | 8,2 | 5,5 | 8,5 | 36 | 12,7 | 2/- | 100 | 1,19 |
701610 | FCPC-u | 10,2 | 5,5 | 8,5 | 36 | 15,7 | 2/- | 100 | 1,19 |
701612 | FCPC-u | 12,2 | 5,5 | 8,5 | 36 | 19,0 | 2/- | 100 | 1,21 |
702508 | FCPC-u | 8,2 | 7,0 | 10,0 | 38 | 13,8 | 2/- | 100 | 1,62 |
702510 | FCPC-u | 10,2 | 7,0 | 10,0 | 38 | 16,0 | 2/- | 100 | 1,65 |
702512 | FCPC-u | 12,2 | 7,0 | 10,0 | 38 | 16,0 | 2/- | 100 | 1,68 |
703508 | FCPC-u | 8,2 | 8,5 | 12,0 | 42 | 17,6 | 2/1 | 100 | 2,75 |
703510 | FCPC-u | 10,2 | 8,5 | 12,0 | 42 | 20,8 | 2/1 | 100 | 2,75 |
703512 | FCPC-u | 12,2 | 8,5 | 12,0 | 42 | 21,7 | 2/1 | 100 | 2,75 |
703516 | FCPC-u | 16,2 | 8,5 | 12,0 | 42 | 21,7 | 2/1 | 100 | 2,75 |
705008 | FCPC-u | 8,2 | 10,0 | 14,0 | 52 | 22,0 | 3/1 | 100 | 4,40 |
705010 | FCPC-u | 10,2 | 10,0 | 14,0 | 52 | 22,0 | 3/1 | 100 | 4,40 |
705012 | FCPC-u | 12,2 | 10,0 | 14,0 | 52 | 25,9 | 3/1 | 100 | 4,40 |
707008 | FCPC-u | 8,2 | 12,0 | 16,5 | 55 | 24,0 | 3/1 | 100 | 6,00 |
707010 | FCPC-u | 10,2 | 12,0 | 16,5 | 55 | 24,0 | 3/1 | 100 | 6,00 |
707012 | FCPC-u | 12,2 | 12,0 | 16,5 | 55 | 24,0 | 3/1 | 100 | 6,00 |
707016 | FCPC-u | 16,2 | 12,0 | 16,5 | 55 | 24,0 | 3/1 | 100 | 6,00 |
709508 | FCPC-u | 8,2 | 13,5 | 18,0 | 65 | 27,8 | 4/2 | 50 | 8,70 |
709510 | FCPC-u | 10,2 | 13,5 | 18,0 | 65 | 27,8 | 4/2 | 50 | 8,70 |
709512 | FCPC-u | 12,2 | 13,5 | 18,0 | 65 | 27,8 | 4/2 | 50 | 8,70 |
709516 | FCPC-u | 16,2 | 13,5 | 18,0 | 65 | 27,8 | 4/2 | 50 | 8,70 |
712010 | FCPC-u | 10,2 | 15,0 | 19,0 | 70 | 31,0 | 4/2 | 50 | 11,30 |
712012 | FCPC-u | 12,2 | 15,0 | 19,0 | 70 | 31,0 | 4/2 | 50 | 11,30 |
712016 | FCPC-u | 16,2 | 15,0 | 19,0 | 70 | 31,0 | 4/2 | 50 | 11,30 |
715012 | FCPC-u | 12,2 | 16,5 | 21,0 | 78 | 31,0 | 4/2 | 75 | 16,10 |
715016 | FCPC-u | 16,2 | 16,5 | 21,0 | 78 | 31,0 | 4/2 | 75 | 16,10 |
715020 | FCPC-u | 20,5 | 16,5 | 21,0 | 78 | 31,0 | 4/2 | 75 | 16,10 |
718512 | FCPC-u | 12,2 | 19,0 | 24,0 | 82 | 34,8 | 4/2 | 25 | 18,50 |
718516 | FCPC-u | 16,2 | 19,0 | 24,0 | 82 | 34,8 | 4/2 | 25 | 18,50 |
718520 | FCPC-u | 20,5 | 19,0 | 24,0 | 82 | 39,0 | 4/2 | 25 | 18,50 |
724010 | FCPC-u | 10,2 | 21,0 | 26,0 | 92 | 37,8 | -/2 | 25 | 27,0 |
724012 | FCPC-u | 12,2 | 21,0 | 26,0 | 92 | 37,8 | -/2 | 25 | 27,0 |
724016 | FCPC-u | 16,2 | 21,0 | 26,0 | 92 | 37,8 | -/2 | 25 | 27,0 |
724020 | FCPC-u | 20,5 | 21,0 | 26,0 | 92 | 37,8 | -/2 | 25 | 27,0 |
730016 | FCPC-u | 16,2 | 23,5 | 31,5 | 100 | 43,0 | -/2 | 20 | 34,0 |
730020 | FCPC-u | 20,5 | 23,5 | 31,5 | 100 | 43,0 | -/2 | 20 | 34,0 |
740012 | FCPC-u | 16,2 | 27,5 | 38,5 | 115 | 49,0 | -/3 | 10 | 68,0 |
740016 | FCPC-u | 20,5 | 27,5 | 38,5 | 115 | 49,0 | -/3 | 10 | 69,0 |
740020 | FCPC-u | 12,2 | 27,5 | 38,5 | 115 | 49,0 | -/3 | 10 | 65,40 |
750016 | FCPC-u | 16,2 | 31,5 | 42,0 | 125 | 56,0 | -/3 | 10 | 83,0 |
750020 | FCPC-u | 20,5 | 31,5 | 42,0 | 125 | 56,0 | -/3 | 10 | 82,0 |
750024 | FCPC-u | 24,5 | 31,5 | 42,0 | 125 | 56,0 | -/3 | 10 | 80,0 |
763016 | FCPC-u | 26,2 | 34,5 | 44,0 | 135 | 65,0 | -/4 | 10 | 79,60 |
763020 | FCPC-u | 20,5 | 34,5 | 44,0 | 135 | 650 | -/4 | 10 | 78,70 |
COPPER BARREL-TYPE TERMINALS FOR CRIMPING
Standard type
Material: Electrolytic copper DIN 40500 Surface: Zinc coated
Used for terminating copper cables (VDE 0295) and ropes (DIN 48201) in power cables, and connection to the electrical circuit by means
of a bolt and nut. Made with a control opening.
At the customer’s request we also make special order terminals.
Kodni broj | Oznaka mm²/Vijak M | d1 mm | d2 mm | d3 mm | L1 mm | L2 mm | Broj presovanja meh./hidr. | Pakovanje kom | Težina g/100kom |
600605 | FCPCu-6/5 | 5,2 | 3,5 | 6,5 | 21 | 11,5 | 2/- | 200 | 0,50 |
600606 | FCPCu-6/6 | 6,5 | 3,5 | 6,5 | 21 | 11,5 | 2/- | 200 | 0,57 |
600608 | FCPCu-6/8 | 8,2 | 3,5 | 6,5 | 23 | 14,0 | 2/- | 200 | 0,66 |
600610 | FCPCu-6/10 | 10,2 | 3,5 | 6,5 | 23 | 14,0 | 2/- | 200 | 0,67 |
601006 | FCPCu-10/6 | 6,2 | 4,5 | 7,0 | 22 | 9,4 | 2/- | 200 | 0,57 |
601008 | FCPCu-10/8 | 8,2 | 4,5 | 7,0 | 25 | 12,5 | 2/- | 200 | 0,68 |
601010 | FCPCu-10/10 | 10,2 | 4,5 | 7,0 | 25 | 17,3 | 2/- | 200 | 0,70 |
601606 | FCPCu-16/6 | 6,2 | 5,5 | 8,0 | 29 | 12,7 | 2/- | 100 | 1,10 |
601608 | FCPCu-16/8 | 8,2 | 5,5 | 8,5 | 29 | 12,7 | 2/- | 100 | 1,13 |
601610 | FCPCu-16/10 | 10,2 | 5,5 | 8,5 | 31 | 15,7 | 2/- | 100 | 1,15 |
601612 | FCPCu-16/12 | 12,2 | 5,5 | 8,5 | 33 | 19,0 | 2/- | 100 | 1,28 |
602506 | FCPCu-25/6 | 6,2 | 7,0 | 10,0 | 32 | 13,8 | 2/- | 100 | 1,30 |
602508 | FCPCu-25/8 | 8,2 | 7,0 | 10,0 | 32 | 13,8 | 2/- | 100 | 1,39 |
602510 | FCPCu-25/10 | 10,2 | 7,0 | 10,0 | 34 | 16,0 | 2/- | 100 | 1,44 |
602512 | FCPCu-25/12 | 12,2 | 7,0 | 10,0 | 36 | – | 2/- | 100 | 1,48 |
603508 | FCPCu-35/8 | 8,2 | 8,5 | 12,0 | 34 | 17,6 | 2/1 | 100 | 2,53 |
603510 | FCPCu-35/10 | 10,2 | 8,5 | 12,0 | 37 | 20,8 | 2/1 | 100 | 2,39 |
603512 | FCPCu-35/12 | 12,2 | 8,5 | 12,0 | 38 | 21,7 | 2/1 | 100 | 2,62 |
605008 | FCPCu-50/8 | 8,2 | 10,0 | 14,0 | 37 | 22,0 | 3/1 | 100 | 2,96 |
605010 | FCPCu-50/10 | 10,2 | 10,0 | 14,0 | 39 | 22,0 | 3/1 | 100 | 3,13 |
605012 | FCPCu-50/12 | 12,2 | 10,0 | 14,0 | 43 | 25,9 | 3/1 | 100 | 3,09 |
605016 | FCPCu-50/16 | 16,2 | 10,0 | 14,0 | 46 | 28,0 | 3/1 | 100 | 3,49 |
607008 | FCPCu-70/8 | 8,2 | 12,0 | 16,5 | 46 | 24,0 | 3/1 | 100 | 4,75 |
607010 | FCPCu-70/10 | 10,2 | 12,0 | 16,5 | 44 | 24,0 | 3/1 | 100 | 5,08 |
607012 | FCPCu-70/12 | 12,2 | 12,0 | 16,5 | 46 | 24,0 | 3/1 | 100 | 4,57 |
607016 | FCPCu-70/16 | 16,2 | 12,0 | 16,5 | 48 | 24,0 | 3/1 | 100 | 4,88 |
609508 | FCPCu-95/8 | 8,2 | 13,5 | 18,0 | 48 | 27,8 | 4/2 | 50 | 6,10 |
609510 | FCPCu-95/10 | 10,2 | 13,5 | 18,0 | 48 | 27,8 | 4/2 | 50 | 5,73 |
609512 | FCPCu-95/12 | 12,2 | 13,5 | 18,0 | 49 | 278 | 4/2 | 50 | 6,06 |
609516 | FCPCu-95/16 | 16,2 | 13,5 | 18,0 | 54 | 27,8 | 4/2 | 50 | 6,48 |
612010 | FCPCu-120/10 | 10,2 | 15,0 | 19,0 | 50 | 31,0 | 4/2 | 50 | 6,07 |
612012 | FCPCu-120/12 | 12,2 | 15,0 | 19,0 | 51 | 31,0 | 4/2 | 50 | 5,93 |
612016 | FCPCu-120/16 | 16,2 | 15,0 | 19,0 | 54 | 31,0 | 4/2 | 50 | 5,71 |
615008 | FCPCu-150/8 | 8,2 | 16,5 | 21,0 | 57 | 31,0 | 4/2 | 75 | 8,45 |
615010 | FCPCu-150/10 | 10,2 | 16,5 | 21,0 | 57 | 31,0 | 4/2 | 75 | 8,14 |
615012 | FCPCu-150/12 | 12,2 | 16,5 | 21,0 | 57 | 31,0 | 4/2 | 75 | 7,81 |
615016 | FCPCu-150/16 | 16,2 | 16,5 | 21,0 | 58 | 31,0 | 4/2 | 50 | 8,05 |
615020 | FCPCu-150/20 | 20,5 | 16,5 | 21,0 | 60 | 36,0 | 4/2 | 50 | 8,44 |
618512 | FCPCu-185/12 | 12,2 | 19,0 | 24,0 | 65 | 34,8 | 4/2 | 50 | 11,46 |
618516 | FCPCu-185/16 | 16,2 | 19,0 | 24,0 | 65 | 34,8 | 4/2 | 50 | 12,01 |
618520 | FCPCu-185/20 | 20,58 | 19,0 | 24,0 | 69 | 39,0 | 4/2 | 25 | 12,40 |
624010 | FCPCu-240/10 | 10,2 | 21,0 | 26,0 | 72 | 37,8 | -/2 | 25 | 14,21 |
624012 | FCPCu-240/12 | 12,2 | 21,0 | 26,0 | 72 | 37,8 | -/2 | 25 | 14,06 |
624016 | FCPCu-240/16 | 16,2 | 21,0 | 26,0 | 72 | 37,8 | -/2 | 25 | 13,90 |
624020 | FCPCu-240/20 | 20,5 | 21,0 | 26,0 | 72 | 37,8 | -/2 | 25 | 13,71 |
630016 | FCPCu-300/16 | 16,2 | 23,5 | 29,5 | 87 | 43,0 | -/2 | 20 | 30,84 |
630020 | FCPCu-300/20 | 20,5 | 23,5 | 29,5 | 87 | 43,0 | -/2 | 20 | 23,00 |
640012 | FCPCu-400/12 | 12,2 | 27,5 | 34,0 | 90 | 49,0 | -/3 | 10 | 33,50 |
640016 | FCPCu-400/16 | 16,2 | 27,5 | 34,0 | 90 | 49,0 | -/3 | 10 | 56,40 |
640020 | FCPCu-400/20 | 20,5 | 27,5 | 34,0 | 90 | 49,0 | -/3 | 10 | 51,33 |
650016 | FCPCu-500/16 | 16,2 | 31,5 | 42,0 | 120 | 56,0 | -/3 | 10 | 46,00 |
650020 | FCPCu-500/20 | 20,5 | 31,5 | 42,0 | 120 | 56,0 | -/3 | 10 | 46,00 |
663016 | FCPCu-630/16 | 16,2 | 34,5 | 44,0 | 125 | 65,0 | -/4 | 10 | 42,00 |
663020 | FCPCu-630/20 | 20,5 | 34,5 | 44,0 | 125 | 65,0 | -/4 | 10 | 42,00 |
NON-INSULATED COPPER CABLE TERMINALS FOR SOLDERING AND CRIMPING
Made in accordance with DIN 46234
Used for terminating copper cables and ropes in power cables and connecting them in the electrical circuit by using a bolt and nut.
Connection with the cable is done by soldering or crimping.
The joint on the terminal is welded.
The terminal surface is zinc coated.
Code number | Designation mm²/Bolt M | d1 mm | d2 mm | d3 mm | L1 mm | L2 mm | Package pcs | Weight g/100pcs |
500153 | FPG-1,5/3 | 3,5 | 1,7 | 3,3 | 11,5 | 6,0 | 100 | 0,039 |
500154 | FPG-1,5/4 | 4,5 | 1,7 | 3,3 | 15,5 | 8,0 | 100 | 0,058 |
500155 | FPG-1,5/5 | 5,5 | 1,7 | 3,3 | 16,0 | 8,0 | 100 | 0,053 |
500253 | FPG-2,5/3 | 3,5 | 2,3 | 4,0 | 16,5 | 8,0 | 100 | 0,072 |
500254 | FPG-2,5/4 | 4,5 | 2,3 | 4,0 | 16,5 | 8,5 | 100 | 0,072 |
500255 | FPG-2,5/5 | 5,5 | 2,3 | 4,0 | 17,5 | 9,5 | 100 | 0,075 |
500256 | FPG-2,5/6 | 6,5 | 2,3 | 4,0 | 21,5 | 12,0 | 100 | 0,102 |
500258 | FPG-2,5/8 | 8,4 | 3,4 | 4,0 | 21,5 | 12,0 | 100 | 0,100 |
500464 | FPG-4,6/4 | 4,5 | 3,4 | 5,5 | 19,5 | 9,5 | 100 | 0,142 |
500465 | FPG-4,6/5 | 5,5 | 3,4 | 5,5 | 19,5 | 9,5 | 100 | 0,139 |
500466 | FPG-4,6/6 | 6,5 | 3,4 | 5,5 | 23,0 | 12,0 | 100 | 0,168 |
500468 | FPG-4,6/8 | 8,4 | 3,4 | 5,5 | 27,0 | 15,0 | 100 | 0,175 |
500469 | FPG-4,6/10 | 10,5 | 3,4 | 5,5 | 27,0 | 15,0 | 100 | 0,170 |
501006 | FPG-10/6 | 6,2 | 4,5 | 6,8 | 27,0 | 14,0 | 300 | 0,285 |
501008 | FPG-10/8 | 8,4 | 4,5 | 6,8 | 27,0 | 14,2 | 300 | 0,287 |
501010 | FPG-10/10 | 10,5 | 4,5 | 6,8 | 27,3 | 14,2 | 300 | 0,260 |
501012 | FPG-10/12 | 12,9 | 4,5 | 6,8 | 16,5 | 20,0 | 300 | 0,406 |
501606 | FPG-16/6 | 6,5 | 5,2 | 7,3 | 29,0 | 14,2 | 300 | 0,337 |
501608 | FPG-16/8 | 8,5 | 5,2 | 7,3 | 29,0 | 14,5 | 300 | 0,345 |
501610 | FPG-16/10 | 10,5 | 5,2 | 7,3 | 29,0 | 14,5 | 300 | 0,293 |
501612 | FPG-16/12 | 12,5 | 5,2 | 7,3 | 33,3 | 16,5 | 300 | 0,383 |
502506 | FPG-25/6 | 6,5 | 6,9 | 9,8 | 33,2 | 16,2 | 200 | 0,735 |
502508 | FPG-25/8 | 8,5 | 6,9 | 9,8 | 33,5 | 16,3 | 200 | 0,720 |
502510 | FPG-25/10 | 10,5 | 6,9 | 9,8 | 33,5 | 16,3 | 200 | 0,676 |
502512 | FPG-25/12 | 15 | 6,9 | 9,8 | 33,5 | 16,3 | 200 | 0,619 |
502516 | FPG-25/16 | 16,9 | 6,9 | 9,8 | 52,0 | 30,0 | 200 | 0,393 |
503506 | FPG-35/6 | 6,5 | 7,7 | 11,5 | 34,2 | 16,3 | 100 | 0,842 |
503508 | FPG-35/8 | 8,4 | 7,7 | 11,5 | 34,2 | 16,3 | 100 | 0,850 |
503510 | FPG-35/10 | 10,5 | 7,7 | 11,5 | 34,2 | 16,3 | 100 | 0,850 |
503512 | FPG-35/12 | 12,5 | 7,7 | 11,5 | 34,2 | 16,3 | 100 | 0,720 |
505008 | FPG-50/8 | 8,4 | 10,1 | 14,1 | 43,0 | 18,0 | 100 | 1,710 |
505010 | FPG-50/10 | 10,5 | 10,1 | 14,1 | 43,0 | 18,2 | 100 | 1,715 |
505012 | FPG-50/12 | 12,5 | 10,1 | 14,1 | 43,0 | 18,2 | 100 | 1,590 |
507010 | FPG-70/10 | 10,5 | 12,0 | 16,0 | 49,0 | 22,2 | 100 | 2,314 |
507012 | FPG-70/12 | 12,5 | 12,0 | 16,0 | 49,0 | 22,2 | 100 | 2,377 |
507016 | FPG-70/16 | 16,5 | 12,0 | 16,0 | 49,0 | 22,5 | 100 | 2,100 |
509510 | FPG-95/10 | 10,5 | 15,0 | 20,0 | 58,2 | 28,0 | 50 | 4,280 |
509512 | FPG-95/12 | 12,5 | 15,0 | 20,0 | 58,2 | 28,0 | 50 | 4,200 |
509516 | FPG-95/16 | 16,5 | 16,5 | 20,0 | 58,2 | 28,3 | 50 | 4,096 |
512010 | FPG-120/10 | 10,5 | 16,5 | 18,0 | 62,0 | 28,3 | 50 | 6,066 |
512012 | FPG-120/12 | 12,5 | 16,5 | 18,0 | 62,0 | 28,3 | 50 | 5,980 |
512016 | FPG-120/16 | 16,5 | 19,4 | 18,0 | 62,2 | 28,3 | 50 | 5,874 |
515012 | FPG-150/12 | 12,7 | 19,4 | 25,5 | 65,0 | 30,2 | 25 | 7,316 |
515016 | FPG-150/16 | 16,5 | 19,4 | 25,5 | 65,0 | 30,2 | 25 | 7,000 |
INSULATED CABLE TERMINAL SETS
Sets are intended for service shops and households (designation indicates number of various cable terminals in the set).
Code number | Designation number of terminals | Weight g/100pcs |
1501100 | FY-100 | 120 |
1501130 | FY-130 | 312 |
FAST-ON NON-INSULATED CABLE TERMINALS – MALE
Used for terminating and connecting small diameter cables in electrical cabinets and devices by crimping.
Code number | Designation mm² | L mm | K mm | Package pcs | Weight g/100pcs |
1640025 | FFM-2.5 | 20.0 | 6.3 | 100/1000 | 88 |
FAST-ON INSULATED CABLE TERMINALS – MALE (DIN 42245)
Used for terminating and connecting small diameter cables in electrical cabinets and devices by crimping.
Code number | Designation mm² | L mm | K mm | Package pcs | Weight g/100pcs |
1410007 | FFM-0.75 | 21.0 | 3.0 | 100/1000 | 43 |
1410105 | FFM-1.5 | 21.0 | 6.3 | 100/1500 | 62 |
1410205 | FFM-2.5 | 21.0 | 6.3 | 100/1500 | 68 |
1410406 | FFM-6 | 23.0 | 6.3 | 100/1000 | 77 |
FAST-ON NON-INSULATED CABLE TERMINALS – OPEN FEMALE
Used for terminating and connecting small diameter cables in electrical cabinets and devices by crimping.
Code number | Designation mm² | L mm | K mm | Package pcs | Weight g/100pcs |
1610007 | FFZ-0.75 | 14.0 | 3.0 | 100/1000 | 50 |
1610105 | FFZ-1.5 | 19.0 | 6.3 | 100/1000 | 70 |
1610205 | FFZ-2.5 | 19.0 | 6.3 | 100/1000 | 80 |
1610406 | FFZ-4-6 | 26.0 | 10.0 | 100/500 | 90 |
1640205 | FFZ-2.5B | 16.0 | 6.3 | 100/500 | 90 |
FAST-ON NON-INSULATED CABLE TERMINALS – FEMALE
Used for terminating and connecting small diameter cables in electrical cabinets and devices by crimping
Code number | Designation mm² | L mm | K mm | package pcs | Weight g/100pcs |
1620105 | FFZ/N-1.5 | 16.5 | 6.3 | 100/1000 | 72 |
1620205 | FFZ/N-2.5 | 16.5 | 6.3 | 100/1000 | 76 |
1620406 | FFZ/N-4-6 | 16.5 | 6.3 | 100/1000 | 88 |