PIN TYPE NON-INSULATED CABLE TERMINALS – DIN 46234
Used for terminating and connecting multi-wire conductors in the electrical circuits of electrical cabinets and devices.
Code number | Designation mm²/Bolt M | L mm | P mm | Package pcs | Weight g/100pcs |
1110015 | FIP-1.5/N | 17.5 | 12.5 | 100/1000 | 57 |
1110046 | FIP-4.6/N | 21.0 | 14.5 | 100/600 | 144 |
PIN TYPE INSULATED CABLE TERMINALS
Used for terminating and connecting multi-wire conductors in the electrical circuits of electrical cabinets and devices.
Code number | Designation mm²/Bolt M | L mm | P mm | Package pcs | Weight g/100pcs |
1110116 | FIP-1.5 | 21.5 | 12.0 | 100/1000 | 73 |
1110125 | FIP-2.5 | 21.5 | 12.0 | 100/1000 | 85 |
1110146 | FIP-6 | 27.5 | 13.0 | 100/500 | 174 |
SPADE TONGUE NON-INSULATED CABLE TERMINALS – DIN 46234
Used for terminating and connecting small diameter conductors in electrical circuits, contacts, relays, etc.
Code number | Designation mm²/Bolt M | L mm | K mm | Package pcs | Weight g/100pcs |
1201153 | FVP 1.5/3N | 16.3 | 6.3 | 100/2000 | 51 |
1201155 | FVP 1.5/5N | 16.0 | 8.0 | 100/4000 | 52 |
1201254 | FVP 2.5/4N | 16.0 | 8.0 | 100/3000 | 57 |
1201255 | FVP 2.5/5N | 16.0 | 8.0 | 100/3000 | 58 |
SPADE TONGUE INSULATED CABLE TERMINALS – DIN 46234
Used for terminating and connecting small diameter conductors in electrical unit circuits
RING TONGUE INSULATED CABLE TERMINALS – DIN 46237
Used for terminating and connecting small diameter conductors in electrical unit circuits
|
|||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||
|
SELF-ADJUSTABLE CLAMP RING WITH BELT
Self-adjustable clamp ring with belt is made of high quality Poliamid, self-extinguishable V0, resistant to heating 110C without deformation. It is produced in grey colour RAL 7035. It is intended for tightening all types of electro , plumbing pipes, heating and gas pipes, for direct tightening of cables on the walls, ceiling, poles, electrical cabinats. Advantages:
Simple and fast mounting on all types of installation with greatest possible saving of work hours. Self-adjustable clamp ring with belt is intended for the places where good mechanical connection is needed, where there is higher temperature and they are suitable for outside use due to their resistance to UV rays. With only two type of self-adjustable clamp ring with belt the outside dimension comprise fi 15-42mm which substantially make assembly work easier.
Code number | Opening diameter mm | Package pcs | Weight kg/100pcs |
5340100 | Ø15-25 | 100 | 0.5 |
5340102 | Ø24-42 | 100 | 1 |
COUPLINGS
These couplings are made of PVC or polyamide. Polyamide couplings with glass fibers are used where high tension strength is needed. Conform to DIN 46320 standards. Couplings are self-extinguishable and resistant to UV-rays and weather conditions. Currently, these are the only couplings being used as they offer complete protection from contact with voltage.
Code number PVC Polyamid |
Type | Thread PG(Re | For cabel diameter mm | Package pcs | Weight kg/100pcs | |
5300091 | 5300071 | FU PG-13,5 | 13,5 | 8-12 | 100 | 1,1/1,5 |
5300092 | 5300072 | FU PG-16 | 16 | 10-14 | 100 | 1,5/1,8 |
5300093 | 5300073 | FU PG-21 | 21 | 13-18 | 100 | 2,6/2,8 |
5300094 | 5300074 | FU PG-29 | 29 | 18-25 | 100 | 3,6/4,3 |
5300095 | 5300075 | FU PG-36 | 36 | 22-32 | 100 | 7,2/8,5 |
ARMORED FUSES
Armored fuses are used to secure residential connections for installation inside attics or in fuse boxes. The housing is made of thermoplastic. At customers demand, they can be delivered with 25 and 63A fuses (indicate when ordering).
Code number | Type | Lenght mm | Width mm | Package pcs | Weight kg/pcs |
5100020 | 63A | 226 | 150 | 10 | 1.40 |
5100026 | 25A | 226 | 150 | 10 | 1.20 |
FUSE SWITCH DISCONNECTORS
Used for protection of electrical grid from short-circuiting and overloading . Intended for install ationon collectors . Easily installed, take up little free space on the installation board . Housing is made of self – extingu is hable polyester reinforced with fiberglass.
Code number | Type | Rated current A | Rated voltage V | Insulation voltage V | Package pcs |
5400115 | FHOO-160/1 | 160 | 690 | 1000 | 1 |
5400116 | FHOO-160/3 | 160 | 690 | 1000 | 1 |
5400124 | FH1-250/1 | 250 | 690 | 1000 | 1 |
5400125 | FH1-250/3 | 250 | 690 | 1000 | 1 |
5400139 | FH2-400/1 | 400 | 690 | 1000 | 1 |
5400140 | FH2-400/3 | 400 | 690 | 1000 | 1 |
5400162 | FH3-630/1 | 630 | 690 | 1000 | 1 |
5400163 | FH3-630/3 | 630 | 690 | 1000 | 1 |
DISJUNCTIVE FUSE BASE
Used for protection of electrical grid from short-circuiting and overloading. Intended for installation on collectors. Easily installed, take up little free space on the installation board and they guarantee protection from accidental contact. Housing is made of self-extinguishable polyester reinforced with fiberglass.
Code number | Type | Rated current A | Rated voltage V | Insulation voltage V | The distance rail mm |
5400037 | SLOO-160/3 | 160 | 690 | 750 | 100 |
5400031 | FD1-160-3 | 160 | 690 | 1000 | 185 |
5400032 | FD1-250/3 | 250 | 690 | 1000 | 185 |
5400033 | FD2-400/3 | 400 | 690 | 1000 | 185 |
5400034 | FD3-630/3 | 630 | 690 | 1000 | 185 |