FUSE RAILS
Used for protection of electrical grid from short-circuiting and overloading. Intended for installation on collectors. Easily installed, take up little free space on the installation board. Housing is made of self-extinguishable polyester reinforced with fiberglass.
Code number | Type | Rated current A | Rated voltaage V | Insulation voltage V | Package pc |
5400041 | L00 – 160/3 | 160 | 690 | 750 | 1 |
5400042 | FR1 – 250/3 | 250 | 690 | 1000 | 1 |
5400043 | FR2 – 400/3 | 400 | 690 | 1000 | 1 |
5400044 | FR3 – 630/3 | 630 | 690 | 1000 | 1 |
DISJUNCTIVE 3-POLE FUSE BASE 50 A (ø14×51)
Used for protection of electrical grid from short-circuiting and overloading. Intended for montage on rails 35mm wide, and for maximum current up to 50A. It is used with cylinder fuses Ø14x51mm for rated current 2, 4, 6, 8, 10, 12, 16, 20, 25, 32, 40 or 50A. Sealing can be done in switched on and switched off position, with and without electric arc fuse. Incoming and outgoing conductors can be connected without screwing, in conductors range 1.5 up to 35 mm².
THREE-POLE KNIFE-BLADE FUSE BASE
Used for protection of electrical networks from short circuiting and overloads.
Note: Protective elements are delivered separately and are used as additional protection for accidental contact with parts under voltage.
Code number | Type | In A | Package pcs | Weight kg/pcs |
5410103 | FPK 160/3 | 160 | 1 | 0.56 |
5410253 | FPK 250/3 | 250 | 1 | 1.76 |
5410403 | FPK 400/3 | 400 | 1 | 3.07 |
SINGLE-POLE KNIFE-BLADE FUSE BASE
Used for protection of electrical networks from short circuiting and overloads.
Note: Protective elements are delivered separately and are used as additional protection for accidental contact with parts under
Code number | Type | In A | Package pcs | Weight kg/pcs |
5410101 | FPK 160/1 | 160 | 3 | 0.18 |
5410251 | FPK 250/1 | 250 | 3 | 0.59 |
5410401 | FPK 400/1 | 400 | 3 | 1.03 |
HANDLE FOR KNIFE-BLADE FUSES
Used for placing and removing knife-blade fuses NV-00 to NV-03. The handle is made of insulated thermoplastic and can be used without protective gloves.
Code number | Type | In A | Package pcs | Weight kg/pcs |
5410001 | NV-00-3 | 2-630 | 10 | 0.27 |
5410002 | PROTECTED | 2-630 | 10 | 0.50 |
SLOTTED PVC CABLE RACEWAYS
Slotted PVC cable raceways are very convenient for cable laying of on-wall installations in offices, laboratories, workshops etc. They facilitate easy installation procedure, swift replacement in case of damages and malfunction and supplementary cable laying. They can secure good mechanical protection for electrical lines. They assure good visibility and give a good esthetic look. They can be installed on every surface, horizontally and vertically. They are very stable and very resistant to chemicals. The sides have cut-outs which can be useful for branching of electrical lines and attaching them to various elements. The sizes of openings are regulated by removing one or more ridges on the sides of the raceways. Raceways are made of very hard, self-extinguishing PVC, with temperature resistance to 70 Co. We standardly produce them in white and grey colors, but customers demand we can produce them in any other color.
Code number white grey |
A x B mm | Lenght mm | Package pcs | Weight kg/pc | |
5063040 | 5063041 | 30×40 | 2000 | 25 | 0.60 |
5063060 | 5063061 | 30×60 | 2000 | 20 | 0.70 |
5064040 | 5064041 | 40×40 | 2000 | 20 | 0.65 |
5064060 | 5064061 | 40×60 | 2000 | 20 | 0.90 |
5066040 | 5066041 | 60×40 | 2000 | 20 | 0.88 |
506060 | 5066061 | 60×60 | 2000 | 16 | 1.14 |
5066120 | 5066121 | 60×120 | 2000 | 10 | 1.92 |
CLOSED PVC CABLE RACEWAYS
Used for contemporaneously cable laying of all kinds of electrical, phone, signal cables and other wire installations on the wall. They facilitate easy installation, swift replacement in case of damages and malfunction and supplementary cable laying. Closed PVC cable raceways give a good mechanical protection of electrical lines. They can enable good visibility and give a good esthetic look. They are very stable and very resistant to chemicals. They can be installed on every surface, horizontally and vertically. Branching of the raceways is done by cutting the sides towards the dimension of separative raceway, and during angled turning, the endings of the raceways are adjusted by cutting, to needed angles. The shutter panel is attached from the upper side, without the use of any tools. The endings of raceways can be closed with the same shutter panel. At the end of the shutter panel, cut of the sides appropriate to the length of the height of the raceway and then heat the specific point of bending and make the shaping adjustments. Raceway 30×10 is intended for installations of phone, electrical and computer wiring in offices, laboratories, workshops etc. It has a longitudinal compartment and with its design can fit into every interior design. Construction of the raceways assures very neat handling of phone and computer lines with energy lines. Raceways are
Code number white grey |
A x B mm | Lenght mm | Package pcs | Weight kg/pc | |
5003017 | 5003018 | 17×17 | 2000 | 50 | 0.28 |
5003010 | 5003011 | 30×10 | 2000 | 50 | 0.42 |
5003020 | 5003021 | 30×20 | 2000 | 50 | 0.47 |
5003040 | 5003041 | 30×40 | 2000 | 25 | 0.63 |
5003060 | 5003061 | 30×60 | 2000 | 20 | 0.82 |
5004040 | 5004041 | 40×40 | 2000 | 20 | 0.74 |
5004060 | 5004061 | 40×60 | 2000 | 20 | 1.03 |
5006040 | 5006041 | 60×40 | 2000 | 20 | 0.94 |
5006060 | 5006061 | 60×60 | 2000 | 15 | 1.22 |
5006120 | 5006121 | 60×120 | 2000 | 10 | 2.06 |
TERMINAL BLOCK RAIL
Used to support terminal blocks joined in a series. The advantage of this rail is that it is calibrated so that the teeth of the elements firmly attach to the rail. Thanks to its narrow tolerance, the rail will not crack.
LIMIT PLATE FOR TERMINAL BLOCKS
These plates are attached to the rail at the end of a block series. Thanks to the specially designed base, the plate fits all standard rails. The plate is made of high-quality polyamide.
- Package: 100 pcs
- Weight: 0, 96 kg/100pcs
- Code number: 5000120
END CAP FOR TERMINAL BLOCKS
Used to end a series of clamps by closing the open part of the clamp. Also used for separating groups of clamps.
Code number | For VS clamp | AxB mm | Package pcs | Weight kg/100pcs |
5000104 | FKN 4-10 | 37×40 | 500 | 0.30 |
5000116 | FKN 16-35 | 42×50 | 500 | 0.42 |