Monthly archives: May 2015
Entries found: 5
INSULATED TAP-OFF CLAMP FIOS 1 AND FIOS 2
Used for tap-off, as well as connection of the tap-off line for household connection to the distributive self-supporting cable bunch using method of penetrating the insulated wire on both distributive and tap-off line. The body of the clamp is made of al.alloy. Insulation of the clamp is secured by a rubber cover resistant to UV rays. The tension controll during the penetration of the insulation of the distributive conductor is achieved with a octagonaltear-off head width 10mm. The connection of the tap-off conductor with the clamp is achieved with screw M10 which can be reused without removing the clamp from the main conduct.
Code number | Designation | Type mm | Main line crose-section | Tap-off line cross-section | Number of tap-off lines |
3804951 | FIOS 1 | 4-54/35-95 | 35-95 | 4-54 | 1 |
3804952 | FIOS 2 | 2x(4-54/35-95) | 35-95 | 4-54 | 2 |
INSULATED ADAPTER FOR SHORT CIRCUIT AND EARTHING WITH CLAMP PC 25-70
It is used for short circuit and earthing of ABC. It is delivered in combination with FIDOS 16-25/35-70, usually for every first branching post or near the end of the power line. It is suitable for short circuit current of 4kA/1s, and continuous current of 200A. Insulation material is made of polyamide resistant to atmospheric conditions and UV rays. Adapter is completely water proof and in accordance with requirements of NFC 33 020.
- Package: 50 pcs
- Weight: 17kg/100 pcs
- Code No: 3802579
INSULATION CONNECTOR FOR TRANSITION FROM LV ABC 25-150 TO BARE CONDUCTOR
It is used for connection of LV brunch self supporting power lines to the non insulated aluminum conductor. Body clamp is made of the polyamide with fibreglass resistant on all atmospheric and mechanical conditions. Contact spikes are made of aluminum alloy. Contact with insulated conductor is achieved with the spikes for piercing the insulation, and the contact with the non insulated conductor is achieved by using plate which increases conductivity. Waterproofing is achieved by special rubber resistant to a UV rays and other atmospheric conditions. For tightening use OK-13 tool, for disassembling use OK-22.It is used for the main no insulated conductor 25-150mm2 and brunch conductor 25-150mm2.
- Package:50pcs
- Weight:180kg/100pcs
- Code no:3802525
INSULATION CONNECTOR FOR TRANSITION FROM LV ABC 2,5-150 TO BARE CONDUCTOR
It is used for connection of LV brunch self supporting power lines to the non insulated aluminum conductor. Body clamp is made of the polyamide with fibreglass resistant to all atmospheric and mechanical conditions. Contact spikes are made of aluminium alloy. Contact with insulated conductor is achieved with the spikes for piercing the insulation, and the contact with the non insulated conductor is achieved by using plate which increases conductivity. Waterproofing is achieved by special rubber resistant to a UV rays and other atmospheric conditions. For tightening use OK-13 tool, for disassembling use OK-22.It is used for the main no insulated conductor cross section 6-150mm2 and brunch insulated conductor 2,5-35mm2. Note: For 2.5mm2 conductors it is necessary to fold the conductor and place inside the clamp.
- Package:40pcs
- Weight:9,5kg/100pcs
- Code no:3802515
INSULATED SEALED BIMETALLIC (Al/Cu) LUGS CPTAU
Used for termination of insulated Al conductors and transition to Cu rail. The conductor,from which the insulation has been removed, is pulled into the lug through the rubber seal thus preventing moisture penetration and appearance of electrolytic corrosion. Hexagonal crimping is carried out directly through the insulation. The points and sequence for crimping are marked on the insulation. For crimping, we recomend “FEMAN” presses with special dies.
Code number | Designation | Type | d1 mm | D mm | d mm | A mm | Crimping die |
3421610 | CPTAU 16 | 16/10 | 10,5 | 16 | 5,3 | 20 | E 140 |
3422512 | CPTAU 25 | 25/12 | 13 | 20 | 6,2 | 24 | E 173 |
3423512 | CPTAU 35 | 35/12 | 13 | 20 | 8,0 | 24 | E 173 |
3425012 | CPTAU 50 | 50/12 | 13 | 20 | 9,0 | 24 | E 173 |
3427012 | CPTAU 70 | 70/12 | 13 | 20 | 10,4 | 24 | E 173 |
3429512 | CPTAU 95 | 95/12 | 13 | 20 | 12,2 | 24 | E 173 |
SEPARABLE JOINTS
Used for connecting and separating conductors for insulated overhead cable lines. The joint body is made of aluminum, protected with the coat of insulation. Joints are entirely insulated providing safety while working under voltage, as well as a safe and long-lasting connection.
Code number | Type mm²/mm² | Package pcs |
3813550 | 35/50 | 10 |
3815050 | 50/50 | 10 |
3817070 | 70/70 | 10 |
3819595 | 95/95 | 10 |
3822096 | 120/120 | 10 |
ADAPTER FOR INSULATION PIERCING CONNECTOR FIDOS 50-150/50-150
Code number | Designation mm²/Screw M | A mm | B mm | C mm | Package pcs | Weight g/100pcs |
3802571 | F1 1 x 6-35 | 80 | 23 | 71 | 50 | 4,2 |
3802572 | F2 2 x 6-35 | 93 | 43 | 78 | 50 | 9,4 |
3802574 | F4 4 x 6-35 | 140 | 43 | 78 | 25 | 16,7 |
ADAPTER 4×1,5-16 mm2 INSULATION PIERCING CONNECTOR FIDOS 16-25/35-70 FA 5
Used as a reducer for connecting clamp FIDOS 16-25/35-70, for house connectors with a possibility of 1, 2, 3 or 4 households using one FIDOS clamp. Adapter is fully isolated and waterproof providing safety during work under voltage as well as a safe and long lasting connection. Adapter enables connection of AL and Cu conductors for house connectors.
INSULATION PIERCING CONNECTOR FIDOS (35)50-150/(35)50-150 – DOUBLE
Used for hard working conditions when connecting branch power line to distributive self-supporting cable bunch under voltage. The waterproof is provided by special rubber, resistant to UV-lights and all other atmospheric conditions. Sealed joint safely prevents an occurrence of electrolyte corrosion, and at the same time it enables connection of Al and Cu brunch power lines to house connections. Clamping is done by moment nut. Clamping force is automatically regulated by a nut which breaks when the proper force is reached – max 24 Nm). For clamp tightening use wrench OK-13 and for dismantling use wrench OK-22.Used for main line of (35) 50 up to 150 mm2 and branch line of (35) 50 up to 150 mm2. When installing under voltage, always use protective gloves.
INSULATION PIERCING CONNECTOR FIDOS (35)50-150/(35)50-150 PC 35-150
Used for connecting branch power line to distributive self-supporting cable bunch under voltage. The waterproof is provided by special rubber, resistant to UV-lights and all other atmospheric conditions. Sealed joint safely prevents an occurrence of electrolyte corrosion, and at the same time it enables connection of Al and Cu brunch power lines to house connections. Clamping is done by moment nut. Position 1 indicates the breaking point of the moment nut (clamp force is automatically regulated by a nut which breaks when the proper force is reached – max 24 Nm). For clamp tightening use wrench OK-13 and for dismantling use wrench OK-22.Used for main line of (35) 50 up to 150 mm2 and branch line of (35) 50 up to 150 mm2. When installing under voltage, always use protective gloves.
- Package: 50 pcs
- Weight: 22 kg/100 pcs
- Code number: 3802580