INSULATED TAP-OFF CLAMP FIOS 1 AND FIOS 2

 

Used for tap-off, as well as connection of the tap-off line for household connection to the distributive self-supporting cable bunch using method of penetrating the insulated wire on both distributive and tap-off line. The body of the clamp is made of al.alloy. Insulation of the clamp is secured by a rubber cover resistant to UV rays. The tension controll during the penetration of the insulation of the distributive conductor is achieved with a octagonaltear-off head width 10mm. The connection of the tap-off conductor with the clamp is achieved with screw M10 which can be reused without removing the clamp from the main conduct.

IINSULATED TAP-OFF CLAMP FIOS 1 AND FIOS 2 IINSULATED TAP-OFF CLAMP FIOS 1 AND FIOS 2

Code number Designation Type mm Main line crose-section  Tap-off  line cross-section  Number of tap-off lines
 3804951  FIOS 1  4-54/35-95  35-95  4-54  1
 3804952  FIOS 2  2x(4-54/35-95)  35-95  4-54  2

 

INSULATED ADAPTER FOR SHORT CIRCUIT AND EARTHING WITH CLAMP PC 25-70

 

It is used for short circuit and earthing of ABC. It is delivered in combination with FIDOS 16-25/35-70, usually for every first branching post or near the end of the power line. It is suitable for short circuit current of 4kA/1s, and continuous current of 200A. Insulation material is made of polyamide resistant to atmospheric conditions and UV rays. Adapter is completely water proof and in accordance with requirements of NFC 33 020.

 

  • Package: 50 pcs
  • Weight: 17kg/100 pcs
  • Code No: 3802579

INSULATED ADAPTER FOR SHORT CIRCUIT AND EARTHING WITH CLAMP PC 25-70

INSULATION CONNECTOR FOR TRANSITION FROM LV ABC 25-150 TO BARE CONDUCTOR

 

It is used for connection of LV brunch self supporting power lines to the non insulated aluminum conductor. Body clamp is made of the polyamide with fibreglass resistant on all atmospheric and mechanical conditions. Contact spikes are made of aluminum alloy. Contact with insulated conductor is achieved with the spikes for piercing the insulation, and the contact with the non insulated conductor is achieved by using plate which increases conductivity. Waterproofing is achieved by special rubber resistant to a UV rays and other atmospheric conditions. For tightening use OK-13 tool, for disassembling use OK-22.It is used for the main no insulated conductor 25-150mm2 and brunch conductor 25-150mm2.

 

  • Package:50pcs
  • Weight:180kg/100pcs
  • Code no:3802525

 

INSULATED WATERPROOF CLAMP FOR CONNECTION OF LV ABC 25-150 TO THE NON-INSULATED CONDUCTOR

 

 

 

 

INSULATION CONNECTOR FOR TRANSITION FROM LV ABC 2,5-150 TO BARE CONDUCTOR

 

It is used for connection of LV brunch self supporting power lines to the non insulated aluminum conductor. Body clamp is made of the polyamide with fibreglass resistant to all atmospheric and mechanical conditions. Contact spikes are made of aluminium alloy. Contact with insulated conductor is achieved with the spikes for piercing the insulation, and the contact with the non insulated conductor is achieved by using plate which increases conductivity. Waterproofing is achieved by special rubber resistant to a UV rays and other atmospheric conditions. For tightening use  OK-13 tool, for disassembling use OK-22.It is used for the main no insulated conductor cross section 6-150mm2 and brunch insulated conductor 2,5-35mm2. Note: For 2.5mm2 conductors it is necessary to fold the conductor and place inside the clamp.

  • Package:40pcs
  • Weight:9,5kg/100pcs
  • Code no:3802515

 

INSULATED WATERPROOF CLAMP FOR CONNECTION OF LV ABC 2,5-150 TO THE NON-INSULATED CONDUCTOR

INSULATED SEALED BIMETALLIC (Al/Cu) LUGS CPTAU

 

Used for termination of insulated Al conductors and transition to Cu rail. The conductor,from which the insulation has been removed, is pulled into the lug through the rubber seal thus preventing moisture penetration and appearance of electrolytic corrosion. Hexagonal crimping is carried out directly through the insulation. The points and sequence for crimping are marked on the insulation. For crimping, we recomend “FEMAN” presses with special dies.

INSULATED WATERPROOF AL-CU BIMETALLIC LUGS CPTAU

 Code number  Designation  Type  d1 mm D mm d mm A mm Crimping die
 3421610  CPTAU 16  16/10  10,5  16  5,3  20  E 140
 3422512  CPTAU 25  25/12  13  20  6,2  24  E 173
 3423512  CPTAU 35  35/12  13  20  8,0  24  E 173
 3425012  CPTAU 50  50/12  13  20  9,0  24  E 173
 3427012  CPTAU 70  70/12  13  20  10,4  24  E 173
 3429512  CPTAU 95  95/12  13  20  12,2  24  E 173

 

SEPARABLE JOINTS

 

Used for connecting and separating conductors for insulated overhead cable lines. The joint body is made of aluminum, protected with the coat of insulation. Joints are entirely insulated providing safety while working under voltage, as well as a safe and long-lasting connection.

SEPARABLE JOINTS

 Code number  Type mm²/mm²  Package pcs
 3813550  35/50  10
 3815050  50/50  10
 3817070  70/70  10
 3819595  95/95  10
 3822096  120/120  10

 

ADAPTER FOR INSULATION PIERCING CONNECTOR FIDOS 50-150/50-150

 

 Used as a reducer for connecting clamp FIDOS 50-150/50-150 for a residential connector with a possibility of connecting 1, 2 and 4 households using one FIDOS clamp. These adapters are completely insulated and waterproof, providing safety while working under voltage as well as a safe and long-lasting connection. Sealed joint with a rubber insert surely prevents an occurence of electrolytic corrosion and it enables connection of Al or Cu conductors for house connectors. Tightening force is automatically regulated by moment nut which breaks when the proper force is reached. For tightening, as well as for adapter disassembling, we recommend the use of wrench OK-13. When installing under power, always use protective gloves. Note: For adapter assembling it is required to use insulated connecting clamp FIDOS with 8 Cu pikes.  ADAPTER FOR INSULATED WATERPROOF CONNECTING CLAMP FIDOS 50-150/50-150
 Code number  Designation mm²/Screw M  A mm  B mm C mm Package pcs Weight g/100pcs
 3802571  F1     1 x 6-35  80  23  71  50  4,2
 3802572  F2    2 x 6-35  93  43  78  50  9,4
 3802574  F4    4 x 6-35  140  43  78  25  16,7

 

ADAPTER 4×1,5-16 mm2 INSULATION PIERCING CONNECTOR FIDOS 16-25/35-70 FA 5

 

Used as a reducer for connecting clamp FIDOS 16-25/35-70, for house connectors with a possibility of 1, 2, 3 or 4 households using one FIDOS clamp. Adapter is fully isolated and waterproof providing safety during work under voltage as well as a safe and long lasting connection. Adapter enables connection of AL and Cu conductors for house connectors.

  • Packing: 100 pcs
  • Weight: 6.8 kg/100 pcs
  • Code: 3802575ADAPTER 4x1,5-16 mm2 FOR INSULATED CONNECTING CLAMP FIDOS 16-25/35-70 FA 5

INSULATION PIERCING CONNECTOR FIDOS (35)50-150/(35)50-150 – DOUBLE

 

Used for hard working conditions when connecting branch power line to distributive self-supporting cable bunch under voltage. The waterproof is provided by special rubber, resistant to UV-lights and all other atmospheric conditions. Sealed joint safely prevents an occurrence of electrolyte corrosion, and at the same time it enables connection of Al and Cu brunch power lines to house connections. Clamping is done by moment nut. Clamping force is automatically regulated by a nut which breaks when the proper force is reached – max 24 Nm). For clamp tightening use wrench OK-13 and for dismantling use wrench OK-22.Used for main line of (35) 50 up to 150 mm2 and branch line of (35) 50 up to 150 mm2. When installing under voltage, always use protective gloves.

  • Package: 25 pcs
  • Weight: 46 kg/100 pcs
  • Code number: 3802590INSULATED WATERPROOF CONNECTING CLAMP DOUBLE FIDOS (35)50-150/(35)50-150

 

 

INSULATION PIERCING CONNECTOR FIDOS (35)50-150/(35)50-150 PC 35-150

 

Used for connecting branch power line to distributive self-supporting cable bunch under voltage. The waterproof is provided by special rubber, resistant to UV-lights and all other atmospheric conditions. Sealed joint safely prevents an occurrence of electrolyte corrosion, and at the same time it enables connection of Al and Cu brunch power lines to house connections. Clamping is done by moment nut. Position 1 indicates the breaking point of the moment nut (clamp force is automatically regulated by a nut which breaks when the proper force is reached – max 24 Nm). For clamp tightening use wrench OK-13 and for dismantling use wrench OK-22.Used for main line of (35) 50 up to 150 mm2 and branch line of (35) 50 up to 150 mm2. When installing under voltage, always use protective gloves.

 

  • Package: 50 pcs
  • Weight: 22 kg/100 pcs
  • Code number: 3802580

 

INSULATED WATERPROOF CONNECTING CLAMP FIDOS (35)50-150/(35)50-150 PC 35-150INSULATED WATERPROOF CONNECTING CLAMP FIDOS (35)50-150/(35)50-150 PC 35-150