JOINT FOR GRATED RACEWAYS
Used to connect perforated ducts. Made of high quality zinc sheet.
Code number | Type | Height mm | Width mm | Lenght mm | Weight kg/pc | Thickness mm |
5000291 | FRK 100-S | 58 | 100 | 95 | 0,11 | 0,70 |
5000292 | FRK 200-S | 58 | 200 | 100 | 0,25 | 0,70 |
5000293 | FRK 300-S | 58 | 300 | 140 | 0,30 | 0,80 |
5000294 | FRK 400-S | 58 | 400 | 200 | 0,77 | 0,80 |
COVERS FOR GRATED RACEWAYS
Used to cover perforated ducts which assures complete protection from mechanical and weather conditions.
Code number | Type | Height mm | Width mm | Lenght mm | Weight kg/pc | Thickness mm |
5000311 | FRK 100-P | 16 | 102 | 2000 | 1,20 | 0,50 |
5000312 | FRK 200-P | 16 | 202 | 2000 | 1,60 | 0,50 |
5000313 | FRK 300-P | 16 | 302 | 2000 | 3,60 | 0,70 |
5000314 | FRK 400-P | 16 | 402 | 2000 | 4,80 | 0,70 |
PERFORATED DUCTS
Used to distribute and lay cables in environments where it is necessary to protect cables from mechanical and weather conditions. Made of high quality zinc sheet. Openings on the duct enable good cable cooling and they are also used to connect perforated ducts supports and joints. When more of these elements are connected, “duct way” is formed.
Note: At customers demand, we can make extra protection by plastification.
Code number | Type | Height mm | Width mm | Lenght mm | Weight kg/pc | Thickness mm |
5000301 | FRK 100 | 60 | 100 | 2000 | 2,30 | 0,70 |
5000302 | FRK 200 | 60 | 200 | 2000 | 3,70 | 0,80 |
5000303 | FRK 300 | 60 | 300 | 2000 | 6,50 | 1,00 |
5000304 | FRK 400 | 60 | 400 | 2000 | 7,10 | 1,00 |
DOUBLE CABLE CLAMP
Used to, easily and swiftly, tighten all types of cables on ceilings or walls.
Made of special thermal plastic.
- Length: 220mm
- Weight: 2, 4 kg/100 pcs
- Code number: 1700035
CABLE CLAMP
Used to, easily and swiftly, tighten all types of cables on ceilings or walls.
Made of special thermal plastic.
- Length: 125mm
- Weight: 1, 4 kg/100 pcs
- Code number: 1700030
SUPPORT SCREW WITH NUT SCREW FOR LOWERED CEILINGS
Necessary when installing lowered ceiling constructions, with universal plaster boards (Knauf, Austroform…) or similar materials. Made in lengths from 50mm to 70mm with screws M3, M4. Maximal force is 2000N. Metal parts are galvanized, and at customers demand we will hot dip galvanize them. When using FEMAN support screw with nut screw for lowered ceilings, installation of ceiling constructions will be swift, easy, reliable and high-quality.
Code number: 5340175
PERFORATED DUCTS
Used to distribute and lay cables in environments where it is necessary to protect cables from mechanical and weather conditions. Made of high quality zinc sheet. Openings on the duct enable good cable cooling and they are also used to connect perforated ducts supports and joints. When more of these elements are connected, “duct way” is formed.
Note: At customers demand, we can make extra protection by plastification.
Code number | Type | Height mm | Width mm | Lenght mm | Weight kg/pc | Thickness mm |
5000301 | FRK 100 | 60 | 100 | 2000 | 2,30 | 0,70 |
5000302 | FRK 200 | 60 | 200 | 2000 | 3,70 | 0,80 |
5000303 | FRK 300 | 60 | 300 | 2000 | 6,50 | 1 |
5000304 | FRK 400 | 60 | 400 | 2000 | 7,10 | 1 |
ATTENTION TAPES
Used as a protection for cables in the ground. Standard width of the tape is 120mm, thickness 0.10mm. Standard packages of tapes are 5kg and 10kg. Made in yellow and red colors.
Code number | Type | Color | A mm |
4703070 | TEL | yellow | 100 |
4703072 | EN | orange | 100 |
CABLE GUARDS
Used for mechanical cable protection in the ground. Made of hard PVC, type 100, according to JUS G.C6.501. The use of these protectors has increased during the years and they are used for protection of energy and telecommunication cables. In practice, they are used instead of bricks. Advantages are: very simple and quick installation, easy manipulation and transport, resistance to flowing currents, good electrical insulation, resistance to corrosion, moisture, acid and alkaline soil, mechanical resistance to impact, ageing resistance. Standard length is 1m. At customers demand, we can produce them in all other lengths. Made in yellow and orange colors.
Code number | Type | Color | A mm | B mm | L mm |
5090010 | TK | žuta | 100 ( 140 ) | 1-2,5 | 1000 |
5090000 | EN | oranž | 100 ( 140 ) | 1-2,5 | 1000 |
LEAD-IN FOR PVC CONDUIT
Use as a lead-in for cables into a cable vault or into an installation.
Code number | Type | Color | A mm | B mm | C mm | L mm |
5090155 | TEL | yellow | 110 | 91 | 3.2 | 600 |